|  		             Flow     cytometry main page   Protocols     main page                          		  |  		                 <---Back            to Flow Cyto Home                       <---              Back to Protocols                    Cell Cycle Analysis by DNA            Content (Propidium            Iodide)         Fixation:                                         - Wash cells by centrifugation (e.g. 200 x g, 5 min, 4°C) in protein-free              buffer, such as Phosphate Buffered Saline without Ca+2              or Mg+2 (PBS).
            -  (Optional) Repeat step 1.
            -  Resuspend at 2 x 106 cells in 1 ml ICE COLD BUFFER.              Cell number will effect staining quality!
               Optional: Use pre-coated or silanized polypropylene              tubes to minimize sticking. Pre-coat tubes overnight with 2% Bovine              Serum Albumin (BSA) in PBS.            - Vortex gently, slowly adding the cell suspension dropwise to 9 ml              of 70% ethanol in a 15 ml polypropylene centrifuge tube (Falcon®              Cat. No. [35]2097). 
               OR: Vortex gently, slowly adding the cell suspension              dropwise to an equal volume of COLD ABSOLUTE ethanol.              Optional: Observe cell preparation with a microcope              to verify minimum cell clumping.            -  Store at 4°C to - 40°C for AT LEAST 2 hours, 12 - 24 hours              is best. Can be stored for up to 2 years before staining.
            -  Centrifuge cells at 200 x g, 10 min, 4°C. 
            -  Resuspend pellet in 3 ml COLD PBS and transfer to Falcon® 12              X 75 mm (Cat. No. [35]2054) polystyrene tubes for staining if other              tubes (polypropylene) were used for the fixation steps above. Falcon®              Cat. No. [35]2235 have nylon filter caps and will remove clumps. 
                               Staining with Propidium            Iodide (PI)                                           -  Wash cells at least once with COLD PBS. Cells may form a diffuse              ring-shaped pellet, so centrifuge longer ( e.g. 200 x g, 10 min, 4°C).
            -  Resuspend cells in 300 - 500 µl               PI/Triton X-100 staining solution : 
              To 10 ml of 0. 1 % (v/v) Triton X-100 (Sigma) in PBS add                2 mg DNAse-free RNAse A (Sigma) and 0.40 ml of 500 µg/ml PI                (e.g., Roche).  Prepare freshly. A stock solution of PI, made                by dissolving 1 mg PI  in 2 ml water, can be stored several                months at 0° to 4°C. (Or buy 500 µg/ml PI from Roche                new Catalog # 11348639001, old Cat. No. 1348639)                   Note: If the RNAse is not DNAse-free, boil a solution                of 2 mg RNAse A  in 1 ml water for 5 min. Aliquot and store                at -20°C.                        -  Incubate 37°C for 15 minutes or for 30 min at 20°C.
            -  Transfer tubes to ice or store at 4°C PROTECTED FROM LIGHT.
            -  Acquire data on flow cytometer within 48 hours (but might last              up to 2 weeks). May require nylon mesh filtration (eg, Filcons, BD              Cat. No. 340627) to remove cell clumps or syringing (25 gauge, UCSD              Storehouse # 7245) to break up cell clumps. Can acquire 5-30 samples              per hour, depending on cell preparation. 
            -  MulticycleAV (IBM-PC) or ModFit LT (Macintosh) is used to fit the              data to various cell cycle models. See below for examples 
                              This a screen            shot of a typical profile from MulticycleAV:                        Click on this            figure to see the full screen.                      Here's a ModFit LT output            example from the same FCS file:                      
 Click on this            figure to see the full screen.                       References:                                - Shapiro, HM, Practical Flow Cytometry, second edition. New York:              Alan R. Liss, Inc; 1988. 353 p.
            -  Darzynkiewicz, Z, Nucleic Acid Analysis. In: Robinson, JP, managing              editor. Current Protocols in Cytometry. New York : J Wiley & Sons,              Inc; 1997. Chapter 7.